feat: portable Windows data layout and launcher package

Separate persistent user data from application code (data/work_tracker.db,
data/uploads, data/storage) with idempotent legacy migration and SQLite
integrity checks. Add offline packaging scripts for a Windows x11 x64
portable ZIP (embeddable Python, Start/Stop/Backup.bat). Fix launcher:
no multiline python -c in BAT and no os.dup2 — uvicorn runs detached with
wvt.log; health wait and busy-port diagnostics included.
This commit is contained in:
Арсентьев Александр
2026-10-20 15:55:04 +03:00
parent a6449a7d70
commit b97d79e13a
28 changed files with 2432 additions and 11 deletions
+67
View File
@@ -0,0 +1,67 @@
@echo off
setlocal EnableExtensions
chcp 65001 >nul
set "APP_HOME=%~dp0"
set "PORT=8000"
set "PY=%APP_HOME%python\python.exe"
set "SCRIPTS=%APP_HOME%scripts"
set "LOGDIR=%APP_HOME%data\logs"
set "STARTLOG=%LOGDIR%\startup.log"
set "APPLOG=%LOGDIR%\wvt.log"
set "CRASHLOG=%LOGDIR%\wvt-crash.log"
set "PIDFILE=%APP_HOME%data\wvt.pid"
if not exist "%LOGDIR%" mkdir "%LOGDIR%"
echo ==== START %DATE% %TIME% ====>> "%STARTLOG%"
echo APP_HOME=%APP_HOME%>> "%STARTLOG%"
echo STEP=begin>> "%STARTLOG%"
if not exist "%PY%" (
echo [ERROR] Local Python not found: %PY%
echo [ERROR] Local Python not found>> "%STARTLOG%"
echo The package is incomplete. Re-extract the ZIP and run Start.bat from the WorkVolumeTracker folder.
if not defined WVT_NO_PAUSE pause
exit /b 1
)
if not exist "%APP_HOME%data" mkdir "%APP_HOME%data"
if not exist "%APP_HOME%backups" mkdir "%APP_HOME%backups"
echo STEP=check_port>> "%STARTLOG%"
"%PY%" "%SCRIPTS%\check_port.py" %PORT% >> "%STARTLOG%" 2>&1
if %ERRORLEVEL% EQU 0 (
echo [ERROR] Port %PORT% is already in use.
echo [ERROR] Port %PORT% busy>> "%STARTLOG%"
echo Stop the other program or run Stop.bat first, then try again.
if not defined WVT_NO_PAUSE pause
exit /b 2
)
echo Starting Work Volume Tracker on http://127.0.0.1:%PORT% ...
echo STEP=start_server>> "%STARTLOG%"
"%PY%" "%SCRIPTS%\start_server.py" %PORT% "%APPLOG%" "%PIDFILE%" >> "%STARTLOG%" 2>&1
echo spawn_exit=%ERRORLEVEL%>> "%STARTLOG%"
echo STEP=wait_health>> "%STARTLOG%"
"%PY%" "%SCRIPTS%\wait_health.py" %PORT% 30 >> "%STARTLOG%" 2>&1
if %ERRORLEVEL% NEQ 0 (
echo [ERROR] The application did not become ready in 30 seconds.
echo [ERROR] health timeout>> "%STARTLOG%"
echo.
echo --- diagnostics ---
"%PY%" "%SCRIPTS%\diagnose_start.py" %PORT% "%APPLOG%" "%PIDFILE%"
"%PY%" "%SCRIPTS%\diagnose_start.py" %PORT% "%APPLOG%" "%PIDFILE%" >> "%STARTLOG%" 2>&1
echo See logs: %APPLOG% and %STARTLOG%
if not defined WVT_NO_PAUSE pause
exit /b 4
)
echo STEP=save_pid>> "%STARTLOG%"
"%PY%" "%SCRIPTS%\save_pid.py" %PORT% "%PIDFILE%" >> "%STARTLOG%" 2>&1
echo STEP=open_browser>> "%STARTLOG%"
if not defined WVT_NO_BROWSER start "" /b "http://127.0.0.1:%PORT%/projects/"
echo Ready. Browser opened http://127.0.0.1:%PORT%/projects/
echo To stop: use Stop.bat
echo READY>> "%STARTLOG%"
exit /b 0