feat: portable Windows data layout and launcher package

Separate persistent user data from application code (data/work_tracker.db,
data/uploads, data/storage) with idempotent legacy migration and SQLite
integrity checks. Add offline packaging scripts for a Windows x11 x64
portable ZIP (embeddable Python, Start/Stop/Backup.bat). Fix launcher:
no multiline python -c in BAT and no os.dup2 — uvicorn runs detached with
wvt.log; health wait and busy-port diagnostics included.
This commit is contained in:
Арсентьев Александр
2026-10-20 15:55:04 +03:00
parent a6449a7d70
commit b97d79e13a
28 changed files with 2432 additions and 11 deletions
@@ -0,0 +1,50 @@
# Fix portable Start.bat — OSError(9) / lost sys.stderr
### Root cause
1. **User failure (`OSError(9, 'Неверный дескриптор')`, `lost sys.stderr`)**
`run_server.py` called `os.dup2(log.fileno(), 1/2)` while the process was started with `start /b`.
The inherited Windows stdio HANDLEs can already be invalid; `dup2` fixes CRT fds but Python/CPython still write through the old `sys.stderr` object / Windows handle → `OSError(9)` and `lost sys.stderr`.
Uvicorn then dies → `startup.log` shows `TIMEOUT` / `health timeout`.
2. **Automation hang** (reproduced in smoke): a child started with `start /b` or `os.spawnv` inherits the BAT’s stdout **pipe**; parent `cmd /c` waits for EOF until the server exits.
`os.spawnv` also does not quote spaces in paths (`финал 179…\WorkVolumeTracker` broke argv).
### Fix
- **No `os.dup2`** in the server process.
- `Start.bat` → `python scripts\start_server.py` (synchronous, short-lived).
- `start_server.py` spawns `run_server.py` with `subprocess.Popen` **list argv** (quotes spaces/Cyrillic) + `DETACHED_PROCESS | CREATE_NEW_PROCESS_GROUP`, `stdin=NUL`, `stdout/stderr=wvt.log` file handles.
- `run_server.py` only replaces Python-level `sys.stdout/stderr` (never OS fds); writes `wvt.pid`; full traceback to `wvt-crash.log`.
- `wait_health.py` uses raw sockets (no urllib).
- `Start.bat`: `startup.log` STEPs, diagnostics (`diagnose_start.py`) on timeout, `WVT_NO_PAUSE` / `WVT_NO_BROWSER` for automation; `pause` on errors in interactive use.
### Changed files
`packaging/Start.bat`, `packaging/scripts/run_server.py`, `packaging/scripts/start_server.py`, `packaging/scripts/wait_health.py`, `packaging/scripts/diagnose_start.py` (already present), `packaging/build_portable.py` (ships scripts, BAT as UTF-8 BOM+CRLF).
Host repo user data, legacy dirs, QA, POST-E2E/BUG-UI, KS-6a — untouched. Staging empty. No commit/push.
### New ZIP
**`C:\MVP-project\_portable_build\WorkVolumeTracker-portable-win11-x64.zip`**
21 853 833 bytes · 2026-10-20
### Tests (clean extract, path with spaces + Cyrillic)
| Check | Result |
|---|---|
| Start.bat rc=0 (~5–12 s) | PASS |
| `/health` 200, `/projects/` 200 | PASS |
| `wvt.log` has `Uvicorn running` | PASS |
| `wvt.log` **no** `OSError` / `lost sys.stderr` | PASS |
| `wvt-crash.log` missing (no crash) | PASS |
| Stop.bat, port closed | PASS |
| **Second** Start.bat after stop | PASS |
| `startup.log` STEPs + READY | PASS |
| Missing `python.exe` / busy port (earlier) | PASS |
### Notes
- `save_pid.py` may still print `PID_NOT_FOUND`; `run_server.py` writes `data\wvt.pid` (used by Stop).
- Browser open uses `start "" /b` and can be skipped via `WVT_NO_BROWSER=1`.